Shipped medical and ammunition catalog audit

Read-only bounded source inventory, 2026-10-25. No production edits, database writes, preview changes, native analysis sessions or client execution. Existing purchase/stack count semantics in local/shop-purchase-research/native/delivery.md were reused and were not re-investigated.

tmp_extract.py reparses exactly18 original resource1000020 item records and 17 relevant/overlapping vendor records with the existing ao_database.py and extract_items.py. It reuses the428-vendor inventory in local/shop-research/catalog.json and795 authored placements in server/gamedata/shops.yaml; no full RDB payload scan or QETS search was repeated.

Retained evidence

Original index anarchy-vanilla-14.9.1/cd_image/data/db/ResourceDatabase.idx SHA-256 46e5dc54af9358cc9bff05f4358e86af630e497bc677f361c133c88073b84d71. Every fresh payload is read by its original (1000020,id) index key, and its digest is recalculated by the existing parser. No native execution is claimed.

Exact medical endpoint definitions

All rows below are native type51005 and have Can30 bit512 (Stackable). The named QL is the endpoint's authored QL, not a discovered vendor rotation range. Their complete records, prices and hashes are retained, rather than treating similar names as interchangeable items.

Family QL1 / QL200 / QL400 IDs Native package212
Simple / Ultra Advanced First-Aid Kit 23314 / 23316 / 160276 25 each
Treatment / HQ Health / Superb Quality Health Treatment Laboratory 25812 / 25811 / 160277 50 each
Simple / Sophisticated / Ultra Sophisticated Nano Kit 85366 / 85367 / 160295 25 each
Basic / Advanced Nano Recharger 25820 / 25821 / 160278 50 each

The regular resource-kit admission test currently admits treatment, nano kits and nano rechargers at these exact QLs; server/resource_kit_test.go lists the complete ten-item set including Startup Treatment Laboratory. Health-only First-Aid kit use remains disabled, as documented in docs/first-aid.md and the same admission test. Identifying its record does not complete its use path.

Startup Treatment Laboratory116628/QL1 has package212=200, price74=0. Startup First-Aid Kit116629/QL1 has package212=300, price74=0. Both are Stackable. These authored capacities differ from current startup issuance quantities and are not evidence of starter-booth stock or free replenishment. Their inclusion here is an explicit comparison boundary, not proposed purchasable stock.

QL200/400 endpoint definitions do not establish that a regular shop sells the exact endpoint or that the current server supports interpolated purchase QLs. The original fields are enough to investigate pairing later; this audit does not invent those pairs, their stock probabilities or rotation.

Exact ordinary ammunition

All four are fixedQL1, type51005, Can30=517=0x205 (includes Stackable512), native package212=100. Descriptions identify compatible weapon concepts; they do not name a booth or supply an explicit category membership key.

ID Original name AmmoType420 Price74
21601 Flamethrower Ammunition 3 80
21605 Bullets 2 25
21609 Energy Weapon Ammo 1 50
21613 Shotgun Shells 4 80

Shells Magazine137259/137260 and Energy Pack Interface137257/137258 are distinct tradeskill component concepts; their names do not make them ordinary ammo packages. They are not included among these four ammunition definitions. These distinctions were checked directly in the existing catalog shards.

Original medical terminal families

The nine regular medical templates below all use category stringDMLA. Raw section23/subtype37 descriptors and all placements are in vendor-records.json. The byte_pair values are preserved as parsed raw fields; their semantic interpretation as generation QL bounds is not independently established here.

Tier Omni Clan Neutral
Basic 99481 OT Basic Medical Supplies 99508 Clan Basic Medic Supplies 99574 Basic Medic Supplies
Advanced 99482 OT Advanced Medic supplies 99509 Clan Advanced Medic supplies 99575 Advanced Medic supplies
Superior 99483 OT Superior Medic Supplies 99529 Clan Superior Medic Supplies 151975 Superior Medic Supplies

Basic descriptors repeatDMLA at bytepairs1/1,5/5,10/10,15/15,20/20. Advanced repeats20/20,30/30,50/50,70/70,90/90. Superior repeats70/70,80/80,90/90,110/110,125/125. The opaque descriptor bytes also differ by tier/faction. Mapping one fixed QL1 subset to everyDMLA terminal would discard these differences and needs an explicit reconstruction-policy boundary.

All eight standard combined rooms have one corresponding regular medical machine: Omni1183/1184/1185, Clan1180/1181/1182, neutral1186/1187. Neutral1187 also has151975 Superior Medic Supplies. Additional authored outdoor/other-room placements are retained; total regular medical placements in the795-registry are19. This is static placement evidence, not a runtime availability claim.

Three additional legacy vendor templates shareDMLA but have no authored static placement in that registry:

ID Name Descriptor byte pairs
25886 Budget MediStim Shop 1/1,2/2,5/5,10/10,10/50
27053 Hack'n Slash Medi Shop 70/125
27062 AllOverYou MediStim Shop 30/80

No nonmedical vendor sharesDMLA in the retained428-template inventory. This does not make the code a recovered explicit list of medical item identities.

Shipped membership statements and their limits

Budget MediStim25886's original description explicitly says it sells budget First Aid Kits, Nano Recharging Kits and other stims. AllOverYou27062 describes selling the same broad families over a wide range. These are direct shipped statements of family membership. They do not identify exact IDs, distinguish Simple Nano Kit from Basic Nano Recharger, specify charge packaging, or enumerate every member ofDMLA. Hack'n Slash's description only calls it a Med shop. The regular faction/tier medical records have empty descriptions.

Budget Ammunition Shop25885 explicitly describes selling budget ammo and other accessories. It references category codesOMMA,CEJE,VWMA,NKMA, each bytepair1/1. Its one authored static placement is identity3221226898, playfield1426. Those same four codes appear in Howard Machine42959 and GregorHallMachine45121; neither has a static placement in this registry. The codes are not present in any standard combined-shop vendor template in this bounded category inventory. The description does not explicitly map the four ordinary ammo IDs to any one of those four codes. Category-name resemblance is not treated as proof.

Engineer Crystals and Ammo31033 has codes10NE,XEMA,NEMA; Karly Desel42119's description also mentions Engineer nano formulas and ammo and sharesXEMA/NEMA. Both lack authored static placements here. Those names/codes do not establish that they sell the four ordinary ammo types above; Engineer-specific ammo is not silently equated to bullet/energy/shell/flamethrower packages.

Howard42959 also referencesOTIM, shared with Tools and Computers templates, and other unrelated equipment categories. Its broad stock is an additional reason not to equate every category occurrence with a booth's exact subset. category-overlaps.json preserves these ambiguities for later reuse.

The shipped help/tips describe using existing first-aid, treatment and nano restoration items. For example TipOfTheDay.txt distinguishes Treatment Laboratory/Recharger recovery from First-Aid in combat, and Improving skills and abilities.txt specifically givesQL1 laboratory's Treatment8 requirement. Startup tips teach using already-owned items. OnSelectShop.txt/OnOpenShop.txt explain generic shopping and staged sales. None of the retained text gives an exact booth-to-item membership table. No standalone PDF manual was found in the supplied client file inventory; the help/tip files are shipped instructions, not a recovered retail-manual stock appendix. Parent separately investigates period external guides.

Observations, inference and remaining gaps

Observed: endpoint IDs, original charge capacities/stack flags/price/ammo types, terminal families, raw descriptors, category sharing, static placements and the explicit broad membership descriptions above.

Inference awaiting corroboration: exact regular medical or ammo booth membership for a selected purchasable subset. A fixed supported subset may be a sensible reconstruction, but its source and scope must remain explicit.

Unknown: full category member lists, original random QL generation/rotation, the opaque descriptor qualifiers' complete semantics, historical package packing/auto-merge and stock-specific stack limits. Existing delivery.md already documents the separate package packing policy; it was not repeated.